PGAINPUTS Command

The PGAINPUTS command shows the simulated PGA input/output values. The user may use this window to specify the input values of PGA+, PGA-, and PGAVDDA. The read-only PGAOUT is the value of PGA output.

Figure 1. PGA Inputs Window
PGA Inputs Window

The PGAINPUTS command can be used at any point to bring up this PGA Inputs window. The window displays the input values of PGA+, PGA-, PGAVDDA and the output value of PGAOUT.

Syntax
  >gdi PGAINPUTS  
Examples
  >gdi PGAINPUTS  

Pull up the PGA Inputs window