The CodeWarrior Ethernet TAP ColdFire BDM probe has a 26-pin connector which automatically supports target system signal levels from 1.8V to 3.3V.
The following figure shows the pin assignments of the probe BDM connector.
The following table lists BDM signal names, direction, pin numbers, descriptions, and drive capabilities of the probe BDM connector.
| BDM pin | Signal mnemonic | Signal direction | Description |
|---|---|---|---|
| 1 | Reserved | From target system | 17pF load |
| 2 | BKPT | From Ethernet TAP probe connector | 50mA driver |
| 3 | GND | - n/a - | |
| 4 | DSCLK | From Ethernet TAP probe connector | 50mA driver |
| 5 | GND | - n/a - | |
| 6 | Reserved | Bi-directional | Open-drain, 100Ohm to ground when asserted by Ethernet TAP probe, 22pF load when not asserted |
| 7 | RESET | Bi-directional | Open-drain. 100Ohm to ground when asserted by Ethernet TAP probe, 22pF load when not asserted1 |
| 8 | DSI | From Ethernet TAP probe connector | 50mA driver |
| 9 | VDD | From target system | 2MOhm pull-down, plus 0.01uF load |
| 10 | DSO | From target system | 17pF load |
| 11 | GND | - n/a - | |
| 12 | PST3 | - n/a - | |
| 13 | PST2 | - n/a - | |
| 14 | PST1 | - n/a - | |
| 15 | PST0 | - n/a - | |
| 16 | DDATA3 | - n/a - | |
| 17 | DDATA2 | - n/a - | |
| 18 | DDATA1 | - n/a - | |
| 19 | DDATA0 | - n/a - | |
| 20 | GND | - n/a - | |
| 21 | Reserved | - n/a - | |
| 22 | Reserved | - n/a - | |
| 23 | GND | - n/a - | |
| 24 | PSTCLK | From target system | 17pF load |
| 25 | Core Voltage | - n/a - | |
| 26 | TEA | From Ethernet TAP probe connector | 50mA driver1 |
The table below provides a general description of each BDM signal and operational requirements.
| BDM pin | Signal mnemonic | Requirement |
|---|---|---|
| 1 | Reserved | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |
| 2 | BKPT | Must be wired to the target system. |
| 3 | GND | Must be wired to the target system. GND is connected directly to the ground inside the Ethernet TAP probe. |
| 4 | DSCLK | DSCLK must be connected to the target system's processor. It is driven by the Ethernet TAP probe as an output with up to 50mA. This signal is the clock for the BDM interface. It is good design practice to keep the trace length short and isolate the trace from other signals. If the trace must be long, then termination may be needed. |
| 5 | GND | Must be wired to the target system. GND is connected directly to the ground inside the Ethernet TAP probe. |
| 6 | Reserved | Need not be wired to the target system. The Ethernet TAP does not currently use this signal. |
| 7 | RESET | Must be wired to the target system. During reset, the Ethernet TAP probe drives RESET to ground through a 100Ohm resistor. |
| 8 | DSI | Must be wired to the target system processor. The Ethernet TAP probe drives the DSI output with up to 50mA. |
| 9 | VDD | Must be wired to the target system. The Ethernet TAP probe uses this signal to determine if power is applied to the target system. The signal is also used as a voltage reference for the signals driven by the Ethernet TAP probe (BKPT, DSCLK, RESET, DSI, and TEA). |
| 10 | DSO | Must be wired to the target system processor. It is an input to the Ethernet TAP probe. |
| 11 | GND | Must be wired to the target system. GND is connected directly to the ground inside the Ethernet TAP probe. |
| 12 | PST3 | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |
| 13 | PST2 | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |
| 14 | PST1 | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |
| 15 | PST0 | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |
| 16 | DDATA3 | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |
| 17 | DDATA2 | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |
| 18 | DDATA1 | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |
| 19 | DDATA0 | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |
| 20 | GND | Must be wired to the target system. GND is connected directly the ground inside the Ethernet TAP probe. |
| 21 | Reserved | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |
| 22 | Reserved | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |
| 23 | GND | Must be wired to the target system. GND is connected directly to the ground inside the Ethernet TAP probe. |
| 24 | PSTCLK | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |
| 25 | Core Voltage | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |
| 26 | TEA | Need not be wired to the target system. The Ethernet TAP probe does not currently use this signal. |