To set trigger C from the
Memory
view:
- Perform steps 1 - 12 as explained in From Variables View
- Right-click the variable a, in the Name column of the Variables view.
- Select the View Memory option from the context menu.
The
Memory
view appears.
- Click the Add Memory Monitor button in the Memory view to open the Monitor Memory dialog box.
Figure 1. Monitor Memory Dialog Box 
- Enter the address of the variable a in the Enter address or expression to monitor text box and click OK.
- In the Memory view, right-click any cell and select Toggle Triggers > Set CFV1 Trace Trigger C.
Figure 2. Setting Trigger C From Memory View 
The
Set Trigger Properties
dialog box appears displaying the address of the variable
a in the
Address
text box.
- Select the Read/Write option from the Access drop-down list and click OK.
- Click Resume to collect trace.
- After a short while, click Suspend to stop the target application.
The data files are generated by the application as shown in Figure 3, after setting trigger C in the Continuous mode on the variable address.